Forum
Home › Forums › Temas ou Discussões › DH parameters – UR10 Calibration › Reply To: DH parameters – UR10 Calibration
Ok, thanks. I checked the unzip trick and it works fine I also noticed that the DH parameters in the XML part are exactly the sum of the DH parameters from the urcontrol.conf.UR10 + the calibration.conf.
I determine the “accuracy” as follows. I scan a ref object with a 3D camera, compute 3 locations. Then I touch the 3 locations with the robot. This gives me a conversion matrix from camera to robot. I then scan a new object and have the robot trace out the outer contour of this new object. The result is not bad, but the points are off, 1 location is good enough, 2 locations have 2 to 3mm error and one has 5mm error. As if there’s some rotation about the robots Z axis of say roughly 0.5 degrees.
The calibration of the camera seems ok, so does the 3 point calibration and now the DH checks out, too. I could remove the tool calibration, just to eliminate another source of error.